RESEARCH ARTICLE


High Flexion Total Knee Arthroplasty – Mid-Term Follow Up of 5 Years



S Endres*, A Wilke
Orthopädie und Unfallchirurgie Elisabeth-Klinik Bigge/Olsberg, Heinrich-Sommer-Str. 4, D-59939, Olsberg, Germany


Article Metrics

CrossRef Citations:
11
Total Statistics:

Full-Text HTML Views: 620
Abstract HTML Views: 395
PDF Downloads: 185
Total Views/Downloads: 1200
Unique Statistics:

Full-Text HTML Views: 406
Abstract HTML Views: 278
PDF Downloads: 129
Total Views/Downloads: 813



Creative Commons License
© Endres and Wilke; Licensee Bentham Open.

open-access license: This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.

* Address correspondence to this author at the Orthopädie und Unfallchirurgie Elisabeth-Klinik Bigge/Olsberg, Heinrich-Sommer-Str. 4, D-59939 Olsberg, Germany; Tel: 0049 2962 803 421; Fax: 0049 2962 803 199; E-mail: s.endres@elisabeth-klinik.de


Abstract

Because of demographic changes, ever greater demands are made of knee replacement systems by patients and surgeons. To meet these demands, knee joint systems with increased flexion are currently being marketed. The main hypothesis of the present study was to evaluate the functional outcome of a high flexion TKA in amid-term follow up. 75 consecutive patients (29 men and 46 women) who had primary arthritis of the knee with similar deformity and range of motion undergo TKA using a NexGen Cr Flex mobile.

Knee Society knee and functional scores and range of motion were assessed.

The follow-up duration was 5 years. There was a highly significant improvement in comparison to the preoperative status (p<0.005). The maximum flexion was 122° in mean and the mean KSS was 167 (SD: 21) at final follow up. Despite positive results in the first 5 postoperative years, the NexGen Cr Flex mobile TKA shows no advantages with regard to ROM and KSS compared to the recent literature. Long-term studies are needed to determine a superiority of high flexion knee implants versus traditional TKA´s.

Keywords: NexGen Cr Flex mobile, mid-term Follow Up, high flexion.



BACKGROUND

Increasing efforts have been made over the past years to improve the flexion properties of TKA´s by refining their design. The basic principle in doing so has been to reduce the back side radius of the condyle of the femoral component, which, in combination with partial posterior coupling, has achieved a maximum flexion angle of over 120° [1]. Although this means that resection of more bone from the posterior femoral condyle is unavoidable, this permits a range of motion extending to deep kneeling and squatting.

Due to demographic changes increasingly young patients require TKA, and this means that the expectations of surgery (e.g. flexion over 120°) are also increasing. It is no longer enough to ensure freedom from pain and to allow everyday activities. In most cases patients expect a free range of motion which is often promised by the advertisement of high flex TKA´s [2].

A knee flexion of 90º to 100º is enough to allow most activities of daily living for elderly people in western countries. Climbing up and down the stairs and sitting on a chair requires 90 to 120º. This range of motion can be achieved with traditional TKA designs whose maximal flexion angle has been reported to range between 100 and 110º [3]. Apart from being influenced by the condition of the patient and surgical technique, the final outcome of a TKA, depends also on the implant design. Therefore, implant manufacturers have attempted to design TKAs that better accommodate knee mechanics in high flexion up to 155° [4, 5] to allow patients activities such as squatting and sitting cross-legged which require knee flexion of 110 to 130º [3].

Recently there have been published similar studies evaluating high flexion knee implants. Kim et al. compared the results of a standard high flexion total knee replacement versus a gender specific high flexion implant type [6]. They found no significant differences between the two groups with regard to the clinical and radiological results, patient satisfaction or complication rate. Another study by Kim et al. showed after a minimum duration of follow-up of two years, that there was no difference in range of motion or clinical and radiographic results between knees that had received high-flexion posterior cruciate-retaining total knee prosthesis and those that had received a high-flexion posterior cruciate-substituting total knee prosthesis [7].

We want to present the results of 75 NexGen® CR-Flex Mobile TKA´s performed by a single surgeon (prosthetic system with high flexion capacity, Zimmer) in a 100% mid-term follow up of 5 years and try to compare the functional outcome with the recent literature on TKA´s, especially on traditional TKA´s

METHODS

Study Design

Between January 2005 and January 2006 75 NexGen® Cr-Flex Mobile (Zimmer) TKA´s were performed by the author due to primary osteoarthritis. None of the patients received a bilateral TKA (Table 1).

Table 1.

Patient Characteristics Preoperative (All Patients Received a Total Knee Arthroplasty Only on One Side)


(Mean Values)
KSS 99 (SD: 12)
Maximum Flexion 82° (SD: 6.5°)
Flexion contracture 8.9° (SD: 9.1°)
BMI 26.6 (SD: 2.8)
Age 65.4 (SD: 8.1)
Gender m/w = 29/46
Varus/Valgus 54/21
Lost to follow Up None

The study protocol of this retrospective study, including the consent forms, was approved by the institutional review board of the University hospital of Marburg, Germany. A detailed informed consent form was signed by each patient, and all information was kept confidential.

Patients received preoperative single shot antibiotic prophylaxis with Cefuroxim 1.5g (if renal function allowed). A tourniquet was used after exsanguination using an Esmarch bandage. All patients received thromboprophylaxis with Mono-Embolex 0.3 once daily.

All TKA procedures were performed by the author (single surgeon) using the anterior Payr-approach with medial arthrotomy. Soft tissues were released in a stepwise manner to achieve ligamentous balance in extension.

Thus, flexion and extension gaps were approximately equal. Sufficient laxity was achieved to enable full extension and flexion and anterior translation, but not too loose to cause abnormal AP motion with resulting impingement or bearing spin out. Tensioning devices were not routinely used. The proximal tibia was resected with the anterior cruciate ligament sacrificed. The PCL was preserved with a bone block.

Both the femoral and the tibial component were completely cemented (Palacos®). Primary patellar resurfacing was not performed in any of the patients.

Hospital Care and Rehabilitation

All patients were inpatients and were observed postoperatively for one day on an intermediate care ward. Physiotherapy was started on the day after surgery with walking exercises on two forearm crutches with maximum weight-bearing and exercise on CPM (continous passive motion). Lymph drainage was added on the second postoperative day.

Investigation Parameters

The follow up was done by the author. ROM, KSS [8] and radiological findings (knee in 3 planes) were evaluated before and 5 years after surgery. Performance of the replaced knee and overall function were assessed using the Knee Society knee and functional scores (maximum score 200, 100 each). The scoring system combines a relatively objective Knee Score that is based on the clinical parameters and a functional Score based on how the patient perceives that the knee functions with specific activities. The maximum Knee Score is 100 points and the maximum functional Score is 100 points (Overall 200 points).

The range of motion especially the maximum passive flexion were assessed using a goniometer with the arms aligned along the long axes of the femur and tibia on the lateral side of the knee joint.

ROM was assessed as primary outcome whereas KSS as secondary outcome. Radiographic assessment was done to identify possible complications like radiolucent lines at the bone cement interface, patella tracking, limb alignment and positioning of the implants. It wasn’t done as a third outcome measurement.

Radiographic assessment consists of a standing scanogram of the leg and lateral radiography to assess tibiofemoral alignment and component positioning. The Merchant’s view was used to assess patellar tracking. The axial patellofemoral position was defined as central (<5° tilted) or as having medial tilt (>5° tilted, with the medial side depressed) or lateral tilt (>5° tilted, with the lateral side depressed) as described by Bindelglass and Vince [9].

Statistical Methods

Data were collated and interpreted by the author to minimise intra-observer error. Differences were compared using t-test. A p value of <0.05 was considered significant. The scores and ROM´s followed a normal distribution.

RESULTS

The follow-up period was 5 years. 75 (100%) knees were followed up clinically and radiological.

Scores and Range of Motion (Table 2)

Table 2.

Comparison ROM and Knee Society Knee and Function Score Preoperative and at Final Follow Up


NexGen Cr Flex Mobile
Maximum Flexion
  Preop 82° (SD: 6.5°)
  Final 122° (SD: 10.6°)
Flexion Contracture
  Preop 8.9° (SD: 9.1°)
  Final 3.9° (SD: 6.6°)
Knee Society Knee and Functional Scores
  Preop 99 (SD: 12)
  Final 167 (SD: 21)

The Range of Motion improved continuously, so a mean flexion of 122° (SD: 10.6°) and a flexion contracture of 3.9° (SD: 6.6°) was achieved after five years. The mean preoperative KSS was 99 (SD: 12; max. 200). 5 years postoperative an improvement was evident. The mean KSS at that time was 167 (SD: 21; max. 200).

Over the period of 5 there was a highly significant improvement in comparison to the preoperative status (p<0.005 for KSS and ROM).

Radiographic Assessment

The tibiofemoral angle was 5–8° valgus in 26 knee joints, 0–4° valgus in 15 joints, and 0–8° varus in 34 knee joints. The mean posterior slope of the tibia was 6.4° (SD: 1.8°). None of the joints showed signs of aseptic loosening at follow-up. The patella was centrally positioned in 67 cases (<5° tilt), showed medial tilt in no cases, lateral tilt without subluxation in 6 cases, and lateral tilt with subluxation in 2 cases (>5° lateral tilt).

Complications

3 patients developed postoperative complications requiring treatment. 2 of these patients developed deep vein thrombosis and had to be treated with anticoagulants for 3 months. The 1 remaining patient demonstrated in the first postoperative week unsatisfactory ROM (<60° flexion), so that a mobilisation under general anaesthesia in combination with a peridural catheter for analgesia was done. Implant-specific complications like aseptic lossening, dislocation of the polyethylene insert, etc. were not seen over the 5 year follow up. 8 patients with lateral tilt of the patella and subluxation underwent revision surgery during the first postoperative year with patellar resurfacing, which improved their condition.

DISCUSSION

The aim of a TKA design is to restore function and normal knee kinematics so as to minimise the risk of implant failure, particularly in younger patients who are subject to higher revision rates [10]. Mobile bearings are superior to fixed bearings because of the reduced shear stress within the polyethylene and improved wear properties.

The aim of the present study was to evaluate a new multi-radius designed TKA (Zimmer Warsaw, Indiana, USA NexGen Cr-Flex Mobile) in mid-term follow up with regard to the functional outcome and to compare the results to the recent literature, especially with the results of traditional TKA´s.

The main difference to traditional TKA´s is on the one hand the fact that the NexGen CR-Flex Mobile has a groove on the anterior sliding surfaces that provides more room for the patellar tendon on increasing flexion. And on the other hand, that the rotational center of the polyethylene inlay is located on the medial tibial plateau and not centrally as with most other TKA´s. In addition, the radius of the posterior femoral condyle is so that an optimal tibiofemoral contact area can be ensured even on deeper flexion.

But the success of a TKA depends critically on its service life and also on the reduction of pain and restoration of function. As a result of the changed demands that are made of a TKA nowadays, systems with extended flexion have come on the market.

Postoperative knee flexion after total knee arthroplasty (TKA) is important and correlates closely with patient satisfaction and functional level. Many factors may affect postoperative range of flexion after TKA but as shown by Kawamura et Bourne [11] the preoperative range of flexion and the preoperative tibiofemoral varus/valgus angles werethe factors that affected postoperative range of flexion. The tilt angles of the patella and the patellar button may also be factors that affect the postoperative range of flexion. Other factors like BMI (Body Mass Index), surgical approach, age of the patient or patella tilt did not show any correlation with the achievable flexion angle.

Previous studies have produced conflicting findings. For example: Huang et al. [5] found that the mean flexion in patients with high-flexion prosthesis was approximately 10° greater than in those with a standard posterior stabilised implant. Laskin [12] has also previously indicated similar findings. However, some authors [13, 14] have not noted increased flexion when using high-flexion rather than traditional prostheses.

The KSS improved from a mean of 99 before surgery to a mean of 167 at final follow up. Our scores were similar to those of other traditional TKA´s. The maximum flexion of 122° in mean was achieved by the patients already after 2 years [12] and is similar to recent studies [6, 7, 13-24]. Table 3 gives an overview about recently published studies evaluating traditional TKA´s and high flexion TKA´s with main focus on the flexion ability.

Table 3.

Overview About the Recent Literature Especially with Regard to Function/Flexion Ability After TKA


Author Study Design Journal Number of Patients TKA Average Follow Up Average Flexion Angle
Huang HT,
Su JY et al.
Matched pair control J Arthroplasty 2005 25 patients High Flex vs Traditional PS 2.4 years 138° vs 126°
Laskin RS Cohort study Orthopedics 2007 80 Patients Traditional PS vs High Flex PS 2 years 118° vs 133°
Kim YH,
Choi Y et al.
RCT J Bone Joint Surg Br. 2010 138 patients (bilateral) High Flex CR vs Gender Flex 3.25 years 126° vs 124°
Kim YH,
Choi Y et al.
RCT J Bone Joint Surg Am. 2009 250 patients (bilateral) High Flex CR vs High Flex PS 2.3 years 133° vs 135°
Kim YH,
Sohn KS, Kim JS
RCT J Bone Joint Surg Am. 2005 50 patients (bilateral) Traditional LPS vs LPS Flex 2.1 years 135.8° vs 138.6°
Seon JK,
Song EK et al.
RCT Orthopedics 2005 100 patients Traditional CR vs High Flex 2 years 130.7° vs 128.5°
Aglietti P,
Buzzi R et al.
Follow Up J Arthroplasty. 1999 60 patients Traditional LPS vs LPS Flex 10 years 106°
Gill GS,
Joshi AB
Follow Up Am J Knee Surg. 2001 223 patients Traditional TKA CR 16.8 years n.a.
Vince KG,
Insall JN et al.
Follow Up J Bone Joint Surg Br. 1989 58 patients Traditional TKA CR 10-12 years 91.2°
Nutton RW,
van der Linden ML et al.
RCT J Bone Joint Surg Br. 2008 56 patients Traditional PS vs High Flex PS 1 year 121° vs 127°
Seon JK, Park SJ et al. Prospective J Bone Joint Surg Am. 2009 100 patients Traditional CR vs High Flex CR 2 years 134.3° vs 135.3°
Bhan S,
Malhotra R et al.
Prospective J Bone Joint Surg Am. 2005 32 patients Traditional CR 6 years 106.9°
Chaudhary R,
Beaupré LA et al.
RCT J Bone Joint Surg Am. 2008 100 patients Traditional CR vs Traditional PS 2 years 105.9° vs 105.8°

But, in addition to pain reduction and restoration of functionality, survivorship is also a decisive consideration in the success of TKA´s. Thanks to its extended posterior condyle radius which has been broadened all around, the NexGenCr-Flex Mobile System offer a larger contact surface on deep bending and therefore spreads the contact stress over a large area. This may guarantee optimum contact area and counteracts a high degree of polyethylene wear which may lead to an increased survivorship. But this needs to be proven in a long term follow up over 10 to 15 years.

The present study has some limitations. First, the use of KSS addresses functionality in a very limited way. The WOMAC and SF-36 are more responsive measures of the outcomes of TKA´s [25]. Secondly, the mid term follow up makes it difficult to draw conclusions regarding the theoretical advantage of the high flex knee replacement system regarding the lifespan. Despite these problems, we believe that we were able to give accurate information after careful assessment of the performance of this high flexion TKA.

Despite positive results in the first 5 postoperative years, the NexGen Cr Flex mobile TKA shows no significant advantages over time compared to traditional TKA´s or other high flexion TKA´s especially with regard to function and range of motion.

So called high flexion TKA´s have to proof their superiority in the long term follow up (10 to 15 years), with the focus on the degree of polyethylene wear and the possible consequence of aseptic loosening.

REFERENCES

[1] Yamazaki J, Ishigami S, Nagashima M, Yoshino S. Hy-Flex II total knee system and range of motion Arch Orthop Trauma Surg 2002; 122(3): 156-60.
[2] Anouchi YS, McShane M, Kelly F Jr, Elting J, Stiehl J. Range of motion in total knee replacement Clin Orthop 1996; 33: 87-92.
[3] Dennis DA, Komistek RD, Colwell CE, et al. In vivo anteriorposterior femorotibial translation of total knee arthroplasty : a multicenter analysis Clin Orthop 1998; 356: 47-57.
[4] Argenson JA, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM. In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty J Biomech 2005; 38: 277-84.
[5] Huang HT, Su JY, Wang GJ. The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up J Arthroplasty 2005; 20: 674-9.
[6] Kim YH, Choi Y, Kim JS. Comparison of standard and gender-specific posterior-cruciate-retaining high-flexion total knee replacements: a prospective, randomised study J Bone Joint Surg Br 2010; 92(5): 639-45.
[7] Kim YH, Choi Y, Kwon OR, Kim JS. Functional outcome and range of motion of high-flexion posterior cruciate-retaining and high-flexion posterior cruciate-substituting total knee prostheses. A prospective, randomized study J Bone Joint Surg Am 2009; 91(4): 753-60.
[8] Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system Clin Orthop Relat Res 1989; (248): 13-4.
[9] Bindelglass DF, Vince KG. Patellar tilt and subluxation following subvastus and parapatellar approach in total knee arthroplasty. Implication for surgical technique J Arthroplasty 1996; 11(5): 507-11.
[10] Harrysson OL, Robertsson O, Nayfeh JF. Higher cumulative revision rate of knee arthroplasties in younger patients with osteoarthritis Clin Orthop Relat Res 2004; 421: 162-8.
[11] Kawamura H, Bourne RB. Factors affecting range of flexion after total knee arthroplasty J Orthop Sci 2001; 6(3): 248-52.
[12] Endres S, Wilke A. Early experience with the NexGen® CR-Flex Mobile knee arthroplasty system: results of 2-year follow-up Orth Rev 2010; 2(1)
[13] Laskin RS. The effect of a high-flex implant on postoperative flexion after primary total knee arthroplasty Orthopedics 2007; 30(Suppl): 86-.
[14] Kim YH, Sohn KS, Kim JS. Range of motion of standard and high-flexion posterior stabilized total knee prostheses: a prospective, randomized study J Bone Joint Surg [Am] 2005; 87-A: 1470-5.
[15] Seon JK, Song EK, Lee JY. Comparison of range of motion of high-flexion prosthesis and mobile-bearing prosthesis in total knee arthroplasty Orthopedics 2005; 28(Suppl): 1247-50.
[16] Aglietti P, Buzzi R, De Felice R, Giron F. The Insall-Burstein total knee replacement in osteoarthritis: a 10-year minimum follow-up J Arthroplasty 1999; 14(5): 560-.
[17] Gill GS, Joshi AB. Long-term results of cemented, posterior cruciate ligament-retaining total knee arthroplasty in osteoarthritis Am J Knee Surg 2001; 14(4): 209-14.
[18] Ranawat CS, Flynn WF Jr, Saddler S, Hansraj KK, Maynard MJ. Long-term results of the total condylar knee arthroplasty. A 15-year survivorship study Clin Orthop Relat Res 1993; (286): 94-102.
[19] Rand JA, Ilstrup DM. Survivorship analysis of total knee arthroplasty. Cumulative rates of survival of 9200 total knee arthroplasties J Bone Joint Surg Am 1991; 73(3): 397-409.
[20] Vince KG, Insall JN, Kelly MA. The total condylar prosthesis. 10- to 12-year results of a cemented knee replacement J Bone Joint Surg Br 1989; 71(5): 793-.
[21] Nutton RW, van der Linden ML, Rowe PJ, Gaston P, Wade FA. A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components J Bone Joint Surg Br 2008; 90(1): 37-42.
[22] Seon JK, Park SJ, Lee KB, Yoon TR, Kozanek M, Song EK. Range of motion in total knee arthroplasty: a prospective comparison of high-flexion and standard cruciate-retaining designs J Bone Joint Surg Am 2009; 91(3): 672-9.
[23] Bhan S, Malhotra R, Kiran EK, Shukla S, Bijjawara M. A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years J Bone Joint Surg Am 2005; 87(10): 2290-6.
[24] Chaudhary R, Beaupré LA, Johnston DW. Knee range of motion during the first two years after use of posterior cruciate-stabilizing or posterior cruciate-retaining total knee prostheses. A randomized clinical trial J Bone Joint Surg Am 2008; 90(12): 2579-86.
[25] Lingard EA, Katz JN, Wright RJ, Wright EA, Sledge CB. Kinemax Outcomes Group. Validity and responsiveness of the Knee Society Clinical Rating System in comparison with the SF-36 and WOMAC J Bone Joint Surg Am 2001; 83-A(12): 1856-64.